Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Vaccine ; 40(18): 2535-2539, 2022 04 20.
Article in English | MEDLINE | ID: covidwho-1721056

ABSTRACT

BACKGROUND: This study evaluates spike protein IgG antibody response following Oxford-AstraZeneca COVID-19 vaccination using the AbC-19™ lateral flow device. METHODS: Plasma samples were collected from n = 111 individuals from Northern Ireland. The majority were >50 years old and/or clinically vulnerable. Samples were taken at five timepoints from pre-vaccination until 6-months post-first dose. RESULTS: 20.3% of participants had detectable IgG responses pre-vaccination, indicating prior COVID-19. Antibodies were detected in 86.9% of participants three weeks after the first vaccine dose, falling to 74.7% immediately prior to the second dose, and rising to 99% three weeks post-second vaccine. At 6-months post-first dose, this decreased to 90.5%. At all timepoints, previously infected participants had significantly higher antibody levels than those not previously infected. CONCLUSION: This study demonstrates that strong anti-spike protein antibody responses are evoked in almost all individuals that receive two doses of Oxford-AstraZeneca vaccine, and which largely persist beyond six months after first vaccination.


Subject(s)
Antibody Formation , COVID-19 , Antibodies, Viral , COVID-19/prevention & control , COVID-19 Vaccines , Humans , Immunoglobulin G , Middle Aged , Northern Ireland , SARS-CoV-2 , Vaccination
2.
Sci Rep ; 12(1): 1173, 2022 01 21.
Article in English | MEDLINE | ID: covidwho-1642018

ABSTRACT

The urgent need to scale up testing capacity during the COVID-19 pandemic has prompted the rapid development of point-of-care diagnostic tools such as lateral flow immunoassays (LFIA) for large-scale community-based rapid testing. However, studies of how the general public perform when using LFIA tests in different environmental settings are scarce. This user experience (UX) study of 264 participants in Northern Ireland aimed to gather a better understanding of how self-administered LFIA tests were performed by the general public at home. The UX performance was assessed via analysis of a post-test questionnaire including 30 polar questions and 11 7-point Likert scale questions, which covers the multidimensional aspects of UX in terms of ease of use, effectiveness, efficiency, accuracy and satisfaction. Results show that 96.6% of participants completed the test with an overall average UX score of 95.27% [95% confidence interval (CI) 92.71-97.83%], which suggests a good degree of user experience and effectiveness. Efficiency was assessed based on the use of physical resources and human support received, together with the mental effort of self-administering the test measured via NASA Task Load Index (TLX). The results for six TLX subscales show that the participants scored the test highest for mental demand and lowest for physical demand, but the average TLX score suggests that the general public have a relatively low level of mental workload when using LFIA self-testing at home. Five printed LFIA testing results (i.e. the 'simulated' results) were used as the ground truth to assess the participant's performance in interpreting the test results. The overall agreement (accuracy) was 80.63% [95% CI 75.21-86.05%] with a Kappa score 0.67 [95% CI 0.58-0.75] indicating substantial agreement. The users scored lower in confidence when interpreting test results that were weak positive cases (due to the relatively low signal intensity in the test-line) compared to strong positive cases. The end-users also found that the kit was easier to use than they expected (p < 0.001) and 231 of 264 (87.5%) reported that the test kit would meet their requirements if they needed an antibody testing kit. The overall findings provide an insight into the opportunities for improving the design of self-administered SARS-CoV-2 antibody testing kits for the general public and to inform protocols for future UX studies of LFIA rapid test kits.


Subject(s)
Antibodies, Viral/immunology , COVID-19 Serological Testing , COVID-19 , Pandemics , Point-of-Care Testing , SARS-CoV-2/immunology , Adolescent , Adult , Aged , COVID-19/diagnosis , COVID-19/epidemiology , COVID-19/immunology , Child , Female , Humans , Immunoassay , Male , Middle Aged
3.
Sci Rep ; 11(1): 14026, 2021 07 07.
Article in English | MEDLINE | ID: covidwho-1301181

ABSTRACT

Lateral flow immunoassays are low cost, rapid and highly efficacious point-of-care devices, which have been used for SARS-CoV-2 antibody testing by professionals. However, there is a lack of understanding about how self-administered tests are used by the general public for mass testing in different environmental settings. The purpose of this study was to assess the user experience (UX) (including usability) of a self-testing kit to identify COVID-19 antibodies used by a representative sample of the public in their cars, which included 1544 participants in Northern Ireland. The results based on 5-point Likert ratings from a post-test questionnaire achieved an average UX score of 96.03% [95% confidence interval (CI) 95.05-97.01%], suggesting a good degree of user experience. The results of the Wilcoxon rank sum tests suggest that UX scores were independent of the user's age and education level although the confidence in this conclusion could be strengthened by including more participants aged younger than 18 and those with only primary or secondary education. The agreement between the test result as interpreted by the participant and the researcher was 95.85% [95% CI 94.85-96.85%], Kappa score 0.75 [95% CI 0.69-0.81] (indicating substantial agreement). Text analysis via the latent Dirichlet allocation model for the free text responses in the survey suggest that the user experience could be improved for blood-sample collection, by modifying the method of sample transfer to the test device and giving clearer instructions on how to interpret the test results. The overall findings provide an insight into the opportunities for improving the design of SARS-CoV-2 antibody testing kits to be used by the general public and therefore inform protocols for future user experience studies of point-of-care tests.


Subject(s)
Antibodies, Viral/analysis , COVID-19 Testing/statistics & numerical data , Immunoassay/statistics & numerical data , Adolescent , Adult , Antibodies, Viral/immunology , Child , Educational Status , Female , Humans , Male , Middle Aged , Patient Satisfaction , Point-of-Care Systems , Self Administration , Sensitivity and Specificity , Young Adult
4.
BMJ Open ; 11(6): e048142, 2021 06 29.
Article in English | MEDLINE | ID: covidwho-1288393

ABSTRACT

OBJECTIVE: To evaluate the dynamics and longevity of the humoral immune response to SARS-CoV-2 infection and assess the performance of professional use of the UK-RTC AbC-19 Rapid Test lateral flow immunoassay (LFIA) for the target condition of SARS-CoV-2 spike protein IgG antibodies. DESIGN: Nationwide serological study. SETTING: Northern Ireland, UK, May 2020-February 2021. PARTICIPANTS: Plasma samples were collected from a diverse cohort of individuals from the general public (n=279), Northern Ireland healthcare workers (n=195), pre-pandemic blood donations and research studies (n=223) and through a convalescent plasma programme (n=183). Plasma donors (n=101) were followed with sequential samples over 11 months post-symptom onset. MAIN OUTCOME MEASURES: SARS-CoV-2 antibody levels in plasma samples using Roche Elecsys Anti-SARS-CoV-2 IgG/IgA/IgM, Abbott SARS-CoV-2 IgG and EuroImmun IgG SARS-CoV-2 ELISA immunoassays over time. UK-RTC AbC-19 LFIA sensitivity and specificity, estimated using a three-reference standard system to establish a characterised panel of 330 positive and 488 negative SARS-CoV-2 IgG samples. RESULTS: We detected persistence of SARS-CoV-2 IgG antibodies for up to 10 months post-infection, across a minimum of two laboratory immunoassays. On the known positive cohort, the UK-RTC AbC-19 LFIA showed a sensitivity of 97.58% (95.28% to 98.95%) and on known negatives, showed specificity of 99.59% (98.53 % to 99.95%). CONCLUSIONS: Through comprehensive analysis of a cohort of pre-pandemic and pandemic individuals, we show detectable levels of IgG antibodies, lasting over 46 weeks when assessed by EuroImmun ELISA, providing insight to antibody levels at later time points post-infection. We show good laboratory validation performance metrics for the AbC-19 rapid test for SARS-CoV-2 spike protein IgG antibody detection in a laboratory-based setting.


Subject(s)
COVID-19 , Immunoglobulin G , Antibodies, Viral , Antibody Formation , COVID-19/therapy , Cross-Sectional Studies , Humans , Immunization, Passive , Immunoassay , Northern Ireland/epidemiology , SARS-CoV-2 , Sensitivity and Specificity , Spike Glycoprotein, Coronavirus , COVID-19 Serotherapy
SELECTION OF CITATIONS
SEARCH DETAIL